	<title>Comments on: Medical Event Criteria in Prostate Seed Implant / Prostate Brachytherapy</title>
	<atom:link href="http://www.mdphysics.com/medical-event-criteria-in-prostate-seed-implant-prostate-brachytherapy/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.mdphysics.com/medical-event-criteria-in-prostate-seed-implant-prostate-brachytherapy/</link>
	<description>A weblog for and by the medical physics community</description>
	<lastBuildDate>Fri, 28 Oct 2011 02:49:26 -0600</lastBuildDate>
	<generator>http://wordpress.org/?v=2.8.6</generator>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
		<item>
		<title>By: Ronald Scala</title>
		<link>http://www.mdphysics.com/medical-event-criteria-in-prostate-seed-implant-prostate-brachytherapy/comment-page-1/#comment-517</link>
		<dc:creator>Ronald Scala</dc:creator>
		<pubDate>Tue, 16 Mar 2010 18:37:14 +0000</pubDate>
		<guid isPermaLink="false">http://www.mdphysics.com/?p=625#comment-517</guid>
		<description>I do not agree with many criteria listed above.
The D90 criteria sounds rational but you must keep in mind that the pre-implant plan can never be exactly duplicated at implant. Hence the possibility that irreversible seed placement could be such that the dose is outside this criteria. I do not feel that this is a ME if the physician has done his/her best to comply with the plan. The 0.5Sv and 50% criteria are also problematic. Radiation therapy cannot be delivered w/o dose to adjacent tissues. The skin receives more than 0.5Sv in Ext Beam but is not considered a ME. This criteria is only intended for dose delivery mistakes that cause organ irradiation to 0.5Sv above what is expected or otherwise unavoidable. Likewise with the 50% criteria. Seed placement is cannot be exact enough to ensure a &quot;tissue&quot; will not receive 50% more than the pretreatment plan showed. Last, three seeds in the bladder wall is in no way a meaningful criteria since seed dislodging is not a always or often the result of incorrect seed placement.

R Scala, MS</description>
		<content:encoded><![CDATA[<p>I do not agree with many criteria listed above.<br />
The D90 criteria sounds rational but you must keep in mind that the pre-implant plan can never be exactly duplicated at implant. Hence the possibility that irreversible seed placement could be such that the dose is outside this criteria. I do not feel that this is a ME if the physician has done his/her best to comply with the plan. The 0.5Sv and 50% criteria are also problematic. Radiation therapy cannot be delivered w/o dose to adjacent tissues. The skin receives more than 0.5Sv in Ext Beam but is not considered a ME. This criteria is only intended for dose delivery mistakes that cause organ irradiation to 0.5Sv above what is expected or otherwise unavoidable. Likewise with the 50% criteria. Seed placement is cannot be exact enough to ensure a &#8220;tissue&#8221; will not receive 50% more than the pretreatment plan showed. Last, three seeds in the bladder wall is in no way a meaningful criteria since seed dislodging is not a always or often the result of incorrect seed placement.</p>
<p>R Scala, MS</p>